They can, for findable reasons: a stopped or worn fan, a sump cover left unsealed after pump work, settling that opens new cracks, or a renovation that changed the foundation or airflow. A working, maintained system holds its result.
More detail
Rebound is rarely mysterious. The fan is the first suspect, since it is the only moving part: a tripped breaker, a failed capacitor, or plain bearing death all read as level liquid on the manometer. Seals are second: sump covers removed for pump service and set back loose are a classic, and so is new slab penetration, a bathroom rough-in, a floor drain, a post footing, cut after the system was designed. Third is the house changing around the system: finishing the basement moves people closer to the source, air-sealing upstairs strengthens stack effect, a new furnace changes basement pressure. Karst ground adds a local wildcard, since soil-gas pathways can shift with water table and season, which is one more argument for the every-two-years retest habit rather than one triumphant post-install number. The response ladder is proportionate: check the gauge, check the seals, retest, and only then talk about adding suction points. The rebound FAQ covers the harder cases.