FAQ

How do I know my radon system is still working?

Direct answer

Check the manometer on the pipe: its liquid should sit unevenly, matching the startup mark. Level liquid means no suction. Then confirm with a retest every couple of years, because a running fan proves airflow, not a low number.

More detail

The U-tube manometer is the system's heartbeat monitor. At startup the installer marks where the liquid sits with the fan pulling; from then on, a glance tells you everything mechanical. Liquid still at the mark: fan pulling as designed. Liquid drifted notably: something changed, perhaps a partially blocked pipe, a tired fan, or a seal opened somewhere, worth a call. Liquid dead level on both sides: the fan has stopped, so check its breaker and switch before assuming the worst. Electronic monitors and alarms do the same job audibly. But the gauge only measures suction. Whether the air upstairs is actually low depends on the whole picture, seals included, and only a measurement answers that, which is why the retest-every-two-years habit applies to mitigated houses as much as unmitigated ones. A good rhythm: glance at the gauge monthly, retest in winter every second year, and keep results together. When the gauge or the number disagrees with history, repair service starts with diagnostics, not parts.

Authoritative sources

Ready to get started?

The inner Bluegrass sits on uranium-bearing limestone, and more than half of tested Fayette County homes have run elevated. Mon-Sat 8am-7pm.

Call (859) 780-8148Text us

Prefer to text? Open your texting app